FE-700 : SRAM Error
SRAM : NG
In most cases, SRAM error can be cleared by carrying out an "ALL CLEAR".
Procedure as follows :
 1) Please take a note of system settings
 - Select Menu with the MODE selector knob
 - Press the [DOWN] key to select Page 2.
 - Press the [+] key to select YES
 - Press the [+] key to confirm selection
 - Please take a note of the settings shown on this screens. Press [+] to change between System menu 1, 2 & 3.
 - To exit the MENU select a different MODE via the MODE selector knob.
 
 2) Please take note of Transducer settings
 - Turn off equipment
 - Hold down any key and turn equipment on. This will activate EXTENSION MODE.
 - Press the [+] key to select TRANSDCUER SETTINGS
 - Please take a note of the settings shown on this screen
 
 3) Clear the memory (Factory Default)
 - Turn off equipment
 - Hold down any key and turn equipment on. This will activate EXTENSION MODE.
 - Press the [UP] key to select CLEAR MEMORY
 - Press the [+] key to select YES
 - Please wait until EXTENSION MODE display returns.
 
 4) Check settings
 - Please now repeat steps 1) and 2) and check the SYSTEM / TRASNDCUER settings.
 - Please adjust the settings to match the previous recorded information
 
If issues still persist after ALL CLEAR has been carried out, we would suspect the MEM PCB (03P6282).