Contact Us
If you still have questions or prefer to get help directly from an agent, please submit a request.
We’ll get back to you as soon as possible.
iupham@furuno.co.uk
Article
Last Month
Model 1835 / 1935 / 1945 Manuals Operators Manual Installation Manual
VR-3000 Liveplayer V4 : V1.41 This software is for use with VR-3000 VDR using V2.xx System Software V2.xx Remote Alarm Panel will show --4 during normal operation Software Download link : LivePlayerV4ver0141.zip LivePlayer V4 Manual : VR-3000 LivePlayer V4 - OME44372J2_VR3020_LivePlayer_V4.pdf System Requirements : Windows 7 No other versions of Li
DS-85 - Type Approval Certificate DOC_MED_QA1655.pdf ModuleD_DNV_MEDD00002CD_1.pdf ModuleD_Telefication_P112_Issue67.pdf United Kingdom_DNV UK_MERB000052F.pdf United Kingdom_DNV UK_MERD00002CD.pdf
FE-800 - Type Approval Certificate DOC_MED_QA1660.pdf ModuleD_DNV_MEDD00002CD_1.pdf ModuleD_Telefication_P112_Issue67.pdf United Kingdom_DNV UK_MERB000039F.pdf United Kingdom_DNV UK_MERD00002CD.pdf
WASSP Manuals CDX Operators Manual v4.0.pdf DRX_Installation_Manual_7.1.pdf WASSP Sensor Box Installation Manual (with WSP-038) 4.2.pdf WASSP-V123 Reference MANUAL Rev A2.pdf Transducer Manual v2.5.pdf
How to make a backup of data in TimeZero (formerly known as Maxsea) Procedure: Open the TimeZero/Maxsea software (select Navigation option) 1) Click on the blue “TimeZero/Maxsea” logo in the upper left-hand corner. 2) Select “Backup Collection” from the list 3) Select a file location. We would recommend using your Desktop. 4) Choose a file name ***
FAR-3000 - Type Approval Certificate DOC_MED_QA1658.pdf MED_DNV_MEDB00001BE_9.pdf ModuleD_DNV_MEDD00002CD_1.pdf ModuleD_Telefication_P112_Issue67.pdf United Kingdom_DNV UK_MERB00001BE.pdf United Kingdom_DNV UK_MERD00002CD.pdf
FE-700 Manuals Operators Manual Installation Manual
FA-170 Manuals Operators Manual Installation Manual
GP-170 - Type Approval Certificate DOC_MED_QA1664.pdf MED_DNV_MEDB000039D_6.pdf ModuleD_DNV_MEDD00002CD_1.pdf ModuleD_Telefication_P112_Issue67.pdf United Kingdom_DNV UK_MERB000039D.pdf United Kingdom_DNV UK_MERD00002CD.pdf
FAR-3000 Manuals Operators Manual Installation Manual
GP-150 Manuals Operators Manual Installation Manual
GPS Rollover - 2022 The next GPS rollover event will occur on January 2nd 2022. A list of effected units is shown below. When the rollover occurs, the effected GPS units will show the wrong position and incorrect date of May 19th 2002. Positional Fix can be restored by carrying out a Cold Start. Details below. The incorrect date cannot not be res
VR-7000 Liveplayer V5 : V1.63 This software package includes 2 x different versions : VR-7000 - Compatible with VR-7000 running V1.20 or higher VR-7000 Previous Versions - Compatible with VR-7000 running V1.10 or earlier Software Download link : LivePlayerV5,MaintenanceViewer.zip Liveplayer V5 Manual : OME44851J_VR7030_LivePlayer.pdf
How to open a backup collection in TimeZero (formerly known as Maxsea) Please note: Opening a backup collection on the PC will overwrite all data on the PC. It is not a way of sharing data but the most complete way of transferring data. Procedure: Prior to starting this procedure please copy the TzBackup data from your removable media onto the PC,
Furuno Transducer Compatibility Guide Download PDF : Transducer Guide.pdf Download Excel Spreadsheet : Transducer Guide Excel.xls
BR-500 - Type Approval Certificate DOC_MED_QA1653.pdf ModuleD_DNV_MEDD00002CD_1.pdf ModuleD_Telefication_P112_Issue67.pdf United Kingdom_DNV UK_MERB000011T.pdf United Kingdom_DNV UK_MERD00002CD.pdf
SSAS - How to access SSAS Manager Mode All SSAS-related settings are set in the SSAS manager mode. Do the following to access this mode : FELCOM-15 : Press [F8] then [2] to show System menu FELCOM-16/18/19 : Press [F8] then [1] to show System menu When in the System menu, select "Command Window" Enter Job No. : ssas manager Enter Password : ship s
GP-1670 / GP-1870 - Chart cards not reading once inserted Please check the position of the switch on the side of the card. If set incorrectly the chart card will fail to read. Testing using this method will cause no hard to the unit and always worth checking before sending the unit in for inspection. Please note: Before removing or inserting your
SSAS - How to carry out a SSAS Test To carry out a SSAS Test : Enable SSAS Manager Mode Press [F7] key to display "Options" menu Select "Test" Press [4] "Distress/SSAS Button Test" Select "Yes" to start the test Whilst in Test mode, the display will show the message "Caution : Test Mode" and will sound an alarm. You have 2 x Options : Test SSAS bu
To reset the IMN number, carry out the following procedure : 1) Press F8 key to access Setup Menu 2) Select "System Setup" 3) Highlight the IMN number 4) Hold [ALT] and type I M N 5) IMN number will now be erased allowing user to enter new number 6) Press [ESC] to exit setup menu. Pop up window will appear asking to Update changes. Select YES
FAR-2xx8 Manuals Operators Manual Installation Manual
GS-100 - Type Approval Certificate DOC_MED_QA1665.pdf MED_DNV_MEDB000039C_4.pdf MED_DNV_MEDB000039H_4.pdf ModuleD_DNV_MEDD00002CD_1.pdf United Kingdom_DNV UK_MERB000039C.pdf United Kingdom_DNV UK_MERB000039H.pdf United Kingdom_DNV UK_MERD00002CD.pdf
FM-8900 Manuals Operators Manual Installation Manual
FAR-2xx8 Type Approval Certificate DOC_MED_QA1657.pdf MED_DNV_MEDB00002AU_8.pdf ModuleD_DNV_MEDD00002CD_1.pdf ModuleD_Telefication_P112_Issue67.pdf United Kingdom_DNV UK_MERB00002AU.pdf United Kingdom_DNV UK_MERD00002CD.pdf
DS-60 - Type Approval Certificate DOC_MED_QA1654.pdf ModuleD_DNV_MEDD00002CD_1.pdf ModuleD_Telefication_P112_Issue67.pdf United Kingdom_DNV UK_MERB000008R.pdf United Kingdom_DNV UK_MERD00002CD.pdf
Azimuth / Headline Errors informs us the Radar Processor can not detect Antenna Rotation. - The Radar system may show additional errors such as Trigger or Video. In most cases, resolving the Headline / Azimuth errors will clear all other alarms. - If the Radar System shows RF error at any point, please contact your nearest Service Provider for addit
Products : FELCOM 15 FELCOM 16 FELCOM 18 FELCOM 19 Reported issue : Equipment showing incorrect date (2003) Issue occurred on 17 August 2022 (17/08/2022) Solution : If you experience symptoms, update the equipment software to the latest version and set the date manually. Note: Software updates do not reset the date and must be set manually. E
DRS4D-NXT - Manual Installation Manual
DS-60 : Manuals Operators Manual Installation Manual
NavNet TZT - Manuals (GEN1) Operators Manual Installation Manual - TZT9 / TZT14 Installation Manual - TZTBB
FCV-38 Manuals Operators Manual Installation Manual
SSAS - How to change Report Destination and Message Contents When the SSAS is activated, the SSAS Report is sent according to the pre-set Report Destination and the pre-set Message Content, as shown in the SSAS Report menu. To adjust these settings, the terminal must be in SSAS Manager Mode Report Destination Press [F5] to open Reports menu Select "
SC-50 : How to Check Software Version Turn ON the unit Press the MENU key and select software version from the menu You will see the below screen displayed. The last 4 digits are the software version for both the processor and display unit. In the below example you have V1.02 for both Display and Processor as highlighted.
All the keys of the display unit are locked by default. To unlock the monitor controls : 1. Turn off the monitor unit. 2. Hold the PIP key whilst powering the monitor back on. Hold the PIP key for more than five seconds. The key operation is now unlocked. Note: If the display slide switch is ON, power of the display is controlled by the connect
FMD-3200 - Type Approval Certificate DOC_MED_QA1662.pdf DOC_MED_QA1663.pdf DOC_MED_QA1667.pdf DOC_MED_QA1668.pdf DOC_MED_QA1669.pdf DOC_MED_QA1670.pdf MED_DNV_MEDB00001AV_10.pdf MED_DNV_MEDB00001G6_3.pdf MED_DNV_MEDB000045U_1.pdf ModuleD_DNV_MEDD00002CD_1.pdf ModuleD_Telefication_P112_Issue67.pdf United Kingdom_DNV UK_MERB00000AJ.pdf United Kingdom_
NavNet MFD-8 / MFD-12 - Manuals Operators Manual Installation Manual
If your ECDIS shows the error message "No Connection to e-Token" it is informing you that the system can not detect the C-MAP Dongle. FMD-3100 The FMD-3100 ECDIS is not supplied with a CMAP Dongle. If you get the above error message please carry out the below steps : - Please go to the Charts section (Top Menu Bar). - Select Licences - Go to the C
How to carry out Tune Initialize After carrying out a magnetron replacement, it is recommended to carry out the Tune Initialize process. Please note this only applies to Magnetron Radars. Set Radar to 12NM Set Gain to 70 Set Sea to 50 Set Rain to 0 1) Click on [TUNE AUTO] button to change Tune function to [TUNE MAN] 2) Move cursor over Tune bar nex
NX-700 - Type Approval Certificate DOC_MED_QA1678.pdf ModuleD_DNV_MEDD00002CD_1.pdf ModuleD_Telefication_P112_Issue67.pdf United Kingdom_DNV UK_MERB000089E.pdf United Kingdom_DNV UK_MERD00002CD.pdf
FAR-2xx7 Manuals Operators Manual Installation Manual
VR-7000 - Type Approval Certificate DOC_MED_QA1671.pdf ModuleD_DNV_MEDD00002CD_1.pdf United Kingdom_DNV UK_MERB000039E.pdf United Kingdom_DNV UK_MERD00002CD.pdf
What is the difference between a NX-700A & NX-700B The main difference between the NX-700A & NX-700B is the Printer. NX-700A : Display, Receiver & Printer NX-700B : Display & Receiver only Operation and performance is the same between both models.
FM-8900 - Type Approval Certificate DOC_MED_QA1674.pdf MED_Telefication_222120007AA_01.pdf MED_Telefication_222120010AA_01.pdf ModuleD_DNV_MEDD00002CD_1.pdf ModuleD_Telefication_P112_Issue67.pdf United Kingdom_DNV UK_MERB0000896.pdf United Kingdom_DNV UK_MERD00002CD.pdf
FMD-3100 - Type Approval Certificate DOC_MED_QA1661.pdf ModuleD_DNV_MEDD00002CD_1.pdf ModuleD_Telefication_P112_Issue67.pdf United Kingdom_DNV UK_MERB00001MN.pdf United Kingdom_DNV UK_MERD00002CD.pdf
FELCOM-18 - Type Approval Certificate DOC_MED_QA1673.pdf MED_Telefication_222120006AA_00.pdf MED_Telefication_222120009AA_00.pdf ModuleD_DNV_MEDD00002CD_1.pdf ModuleD_Telefication_P112_Issue67.pdf United Kingdom_DNV UK_MERB0000894.pdf United Kingdom_DNV UK_MERD00002CD.pdf
FAR-2xx8 - Brochure FAR-23x8 Series Brochure FAR-22x8 Series Brochure
SC-70 / SC-130 - Type Approval Certificate DOC_MED_QA1666.pdf MED_DNV_MEDB00001BW_2.pdf MED_DNV_MEDB00001BX_2.pdf MED_DNV_MEDB00001BY_2.pdf ModuleD_DNV_MEDD00002CD_1.pdf ModuleD_Telefication_P112_Issue67.pdf United Kingdom_DNV UK_MERB00001BW.pdf United Kingdom_DNV UK_MERD00002CD.pdf
In most cases, SRAM error can be cleared by carrying out an "ALL CLEAR". Procedure as follows : 1) Please take a note of system settings - Select Menu with the MODE selector knob - Press the [DOWN] key to select Page 2. - Press the [+] key to select YES - Press the [+] key to confirm selection - Please take a note of the settings shown on this scr
Please follow the below steps to assist with diagnosing the cause of your FAR-2xx7 Radar Shut Down issue Decision Tree Please check external power supply. 220 VAC / 100 VAC / 24 VDC Voltage OK Voltage NG Add Button Please check RPU-130 Fuse. Does Radar now Power on? Yes No Add Button If you found this Guide helpful, please click the Thumbs up butto
Magnetron Lead Wire Change The magnetron lead wire is changed to one with better flame resistance. As a result the colour of the lead wire / cable has changed. Terminal Colour of OLD Wire Colour of NEW Wire Heater (H) Green Pale Green / Water Blue Heater Cathode (HK) Yellow Pale Yellow / White Magnetrons effected as follows : M1458F M1517 MAF1421B
FAR-15x8 - Type Approval Certificate DOC_MED_QA1656.pdf ModuleD_DNV_MEDD00002CD_1.pdf ModuleD_Telefication_P112_Issue67.pdf United Kingdom_DNV UK_MERB00000FC.pdf United Kingdom_DNV UK_MERD00002CD.pdf
FA-170 - Type Approval Certificate DOC_MED_QA1659.pdf MED_DNV_MEDB00000EV_3.pdf ModuleD_DNV_MEDD00002CD_1.pdf ModuleD_Telefication_P112_Issue67.pdf United Kingdom_DNV UK_MERB00000EV.pdf United Kingdom_DNV UK_MERD00002CD.pdf
This is a auto-generated Article of all your definitions within the glossary. Glossary This is a auto-generated Article of all your definitions within the glossary. All
Fish Size Guide The following guide shows the basic tools used to measure Fish Size when using the FCV-38 Fish Finder. For more information, please refer to the Operators Manual : Operators Manual Please Note : For the measurement tool to work, system must be in Split Beam mode (MODE : SB) How to Show / Hide Fish Size Graph 1) Cli
FS-1575 / FS-2575 / FS-5075 - Type Approval Certificate FS-1575 DOC_MED_QA1675.pdf ModuleD_DNV_MEDD00002CD_1.pdf ModuleD_Telefication_P112_Issue67.pdf United Kingdom_DNV UK_MERB0000898.pdf United Kingdom_DNV UK_MERB0000899.pdf United Kingdom_DNV UK_MERD00002CD.pdf FS-2575 DOC_MED_QA1676.pdf ModuleD_DNV_MEDD00002CD_1.pdf ModuleD_Telefication_P112_Iss
FE-800 - Manuals Operators Manual Installation Manual
DRS6A-XClass / DRS12A-XClass / DRS25A-XClass Manuals Installation Manual
VR-7000 Manuals VDR User Guide VDR Data Extraction Procedure (VR-7000) Operators Manual Liveplayer V5 Manual Installation Manual
FAR-15x3 / FAR-15x8 Manuals Operators Manual Installation Manual
When programming a VR-7021F (Jotron Tron40-VDR) please use the new TRON-LINK programming software Once programming is complete you must generate a Programming Report. If when clicking the "Make Report" button you find nothing happens, you can locate the generated report in the following folder on your PC : User\Documents\TronLink-EPIRB-Reports
What is the Maximum Antenna Cable length? When using the standard supply Antenna cable (RW-00135), the maximum cable length is 80M There are options available to extend this distance as detailed in the below table : MAX Length Cable Type Remarks Antenna > RPU-025 80M RW-00135 - Antenna > RPU-025 100M RW-9600 LAN Signal Convertor Kit required A
SSAS - How to reset SSAS To cancel a SSAS transmission, first check that both buttons are set to the off position. There will usually be at least 2 x buttons The buttons are latching type. To stop transmission of SSAS alert : METHOD 1 Make sure all SSAS buttons are in the off position Go to one of the SSAS buttons and press ON > OFF > ON >
The installation menu only appears when you power the display on for the first time. To access the installation menu again : 1. Turn off the monitor unit. 2. Hold the DISP key whilst powering the monitor back on. Hold the DISP key for more than five seconds. The installation menu will now be displayed. Note : If the Monitor keys are locked
NavNet TZT2 - Manuals Operators Manual Installation Manual - TZTL12F / TZTL15F Installation Manual - TZT2BB
To reset the Life Time counter on the MU-190 or MU-231, carry out the following procedure : * Please first check the display keys are unlocked : How to Unlock Key Operation 1) Turn on the monitor whilst holding the [MENU] key. The following menu will appear : 2) Select Other using the arrow keys on the Display 3) Change Elapsed time to "0"
Please be informed that MapMedia 3D (MM3D) charts with Navionics data core type will no longer be available from Mar. 25, 2022 for new purchase, as separately announced by MaxSea/Nobeltec in Jan. 2022. Here is guidance, checked with MapMedia, on further purchase, unlock, etc., regarding Furuno products. Target models: NavNet TZtouch3 series MFDs (
TZTL12/15F Units rebooting on start up or inside general operation NMEA2000 Guidelines On some installation we have seen issues with some installation not adhering to the IAW NMEA 0400 Installation Standard Edition 2014, specifically V4.00 (section 8.3.7.3) which requires NMEA2000 power to be isolated. Most problems are caused by 24VDC vessels using
BR-500 Manuals Operators & Installation Manual
NavNet TZT3 - Manuals Operators Manual Installation Manual - TZT9F Installation Manual - TZT12F Installation Manual - TZT16F Installation Manual - TZT19F
FMD-3200 / FMD-3300 Manuals Operators Manual Installation Manual
FMD-3100 Manuals Operators Manual - NEW (PCU-3010) Installation Manual - NEW (PCU-3010) Operators Manual - OLD (PCU-3000) Installation Manual - OLD (PCU-3000)
SCX-20 update via TZT3 Copy software update folders to the USB root (note that the USB should be formatted to FAT32). Connect USB with software to the back of the TZT3 Display 2. Go to “Initial Setup” > ”Update Network Equipment” > ”SCX-20” 3. Select SCX-20 4. Wait for the update to complete
GP-170 Manuals Operation Manual Installation Manual
SC-70 / SC-130 Manuals Operators Manual
If the AXIS Camera settings are not entered into TimeZero, you may have the below pop up message appear when opening TZ software. To stop this dialog box from popping up, please enter the username/password into the TZ software. TZ logo upper left corner>Options>Camera User : root Password : pass (This is the default username/password, pleas
NavNet MFD-BB - Manuals Operators Manual Installation Manual
TimeZero - Manuals TimeZero Professional v4.0 Manual TimeZero Navigator v4.0 Manual TZ iBoat v2.3
SC-70 : New NMEA-2000 Connector The SC-70 / SC-130 has a new BT-PWR Board. BT-PWR PCB Part Code OLD 20P8233-22 00151554000 NEW 20P8233-33 unchanged The new BT-PWR PCB uses a different Connector for the NMEA-2000 interface. When exchanging the old board for new version, the following adaptor cable is needed : FRU-NMEA-PMM-02 [00159233000]
GP-320B Manual Operators & Installation Manual
FCV-588 / FCV-628 Manuals Operators Manual
Reported issue : Engineer / Customer can connect to VR-7000 via Liveplayer & Maintenance viewer, however they are unable to download config files or playback data. Things to Check : Make sure PC Fixed IP is set correct to match device you are trying to connect too When connecting to DCU or Long Term Storage Device, Set PC IP to : 172.31.16.201 /
VR-3000 / VR-5000 Liveplayer PRO : V3.20 This software is for use with VR-3000 VDR using V1.xx System Software V1.xx Remote Alarm Panel will show --- during normal operation Software Download link : LivePlayerPro_3_20.zip LivePlayer PRO Manual : LivePlayer Pro Manual - OME44182B_VR5034.pdf System Requirements : Windows XP No other versions of Livep
CSH-5L Mk2 / CSH-8L Mk2 Manuals Operators Manual CSH-5L Mk2 Installation Manual CSH-8L Mk2 Installation Manual
FSV-75 Manuals Operators Manual Installation Manual
DFF3 Manuals Operators & Installation Manual
CH-37-BB Manuals Operators Manual Installation Manual
How to carry out Tune Initialize After carrying out a magnetron replacement, it is recommended to carry out the Tune Initialize process. Set Radar to 12NM Set Gain to 70 Set Sea to 50 Set Rain to 0 1) Click on [TUNE AUTO] button to change Tune function to [TUNE MAN] 2) Move cursor over Tune bar next to Tune Button. Make sure cursor hovers over tun
FSV-35 Manuals Operators Manual Installation Manual
CH-500 / CH-600 Manuals Operators Manual Installation Manual
FSV-25 / FSV-25S Manuals Operators Manual Installation Manual
FSS-3BB Manuals Operators Manual Installation Manual
FCV-2100 Manuals Operators Manual Installation Manual
DFF1-UHD Manual Operators & Installation Manual
FCV-295 Manuals Operators Manual Installation Manual
FCV-1900 Manuals Operators Manual Installation Manual
FCV-1150 Manuals Operators Manual Installation Manual
Model 1623 / 1715 Manuals Model 1623 Operators Manual Model 1715 Operators Manual
BBDS1 Manuals Operators & Installation Manual
What is the Maximum Antenna Cable length? When using the standard supply Antenna cable (RW-00135), the maximum cable length between the Antenna & PSU is 5 0M There are options available to extend this distance as detailed in the below table : MAX Length Cable Type Remarks Antenna > PSU 50M RW-00135 - Antenna > PSU 100M RW-9600 LAN Signal C
DRS6A-NXT / DRS12A-NXT / DRS25A-NXT - Manuals Installation Manual
FAR-1416 / FAR-1426 Manuals Operators Manual Installation Manual
If you have lost or forgotten the WiFi password for the DRS4DW radar, please do as follows : 1) Take note of the SSID This is the WiFi device name This can be seen when searching for devices your devices via wifi settings For example : DRS4W 05124027 2) Add 1 number to each digit of the SSID When adding 1 number to "9" it will become "0" In the
IC-307 SSAS - Manuals Operators Manual
FELCOM-250 / FELCOM-500 Manuals Operators Manual Installation Manual
FM-4800 Manuals Operators & Installation Manual
If FBB Handset shows SIP Registration Error, please carry out the following : 1) Connect to Terminal via Laptop/PC. Connection is Ethernet connection. Open Web Broswer. Enter IP address : 192.168.1.1 This IP address is the default address. If it does not work, please contact Ships IT department and check if default IP address has been changed. 2)
We would like to inform Furuno customers that The General Lighthouse Authorities of the UK and Ireland—Trinity House, the Northern Lighthouse Board, and Irish Lights—will discontinue their Differential GPS (DGPS) service in March 2022. Please refer to the following article for more information : Discontinuation of DGPS | Trinity House What does t