GPS Rollover - January 2022

Written by Ian Upham

Updated at September 1st, 2022

Contact Us

If you still have questions or prefer to get help directly from an agent, please submit a request.
We’ll get back to you as soon as possible.

Please fill out the contact form below and we will reply as soon as possible.

  • Latest News
  • Products
    Radar ECDIS VDR TimeZero NavNet TZT NavNet MFD Chart Plotter GPS AIS Communication Echo Sounder Sonar Fish Finder Multi Beam Sonar Current Indicator Compass Autopilot Speed Log BNWAS Instruments Monitors & Displays Envision AR System Power Supply Unit Interfaces
  • Type Approval Certs
+ More

GPS Rollover - 2022


The next GPS rollover event will occur on January 2nd 2022.  

A list of effected units is shown below.

When the rollover occurs, the effected GPS units will show the wrong position and incorrect date of May 19th 2002. 

Positional Fix can be restored by carrying out a Cold Start. Details below.

The incorrect date cannot not be resolved by a Cold Start. To fix this issue you will need to carry out a software update. In some cases, you may be required to replace the GPS unit with a newer model. Full information listed below.



  

GPS Unit


GPS Core

Remedy


GP-80

GN-8096C/D : 4850264 

GN-8097C/D : 4850296

No Remedy Available

GP-90

GN-8096C/D : 4850264 

GN-8097C/D : 4850296

No Remedy Available

GP-150

GN-8096C/D : 4850264 

GN-8097C/D : 4850296

Update to V4.05

GP-1640

GN-8096C/D : 4850264 

GN-8097C/D : 4850296

No Remedy Available

GP-1650

GN-8096C/D : 4850264 

GN-8097C/D : 4850296

No Remedy Available

GP-1850

GN-8096C/D : 4850264 

GN-8097C/D : 4850296

No Remedy Available

GP-7000

GN-8096C/D : 4850264 

GN-8097C/D : 4850296

No Remedy Available

GP-3500

GN-8096C/D : 4850264 

GN-8097C/D : 4850296

Update to V6.03

GP-70 Mk2

GB-97 (GN-8098) : 4850311

No Remedy Available

GP-188

GB-97 (GN-8098) : 4850311

No Remedy Available

GP-280/380/680

GB-97 (GN-8098) : 4850311

No Remedy Available

GP-8000

GB-97 (GN-8098) : 4850311

No Remedy Available

PS-8000 Mk2

GB-97 (GN-8098) : 4850311

No Remedy Available

GPS Unit


GPS Core

Remedy

FRS-1000

GB-97 (GN-8098) : 4850311

No Remedy Available

GP-1800

GB-97 (GN-8098) : 4850311

No Remedy Available

GP-500 Mk2

GB-97 (GN-8098) : 4850311

No Remedy Available

GP-3100 Mk2

GB-97 (GN-8098) : 4850311

No Remedy Available

GP-3300

GB-97 (GN-8098) : 4850311

No Remedy Available

GP-32

GN-8093 : 4850264

No Remedy Available

GP-37

GN-8093 : 4850264

No Remedy Available

GP-33

*Serial Numbers Before : 6412-8194

GN8093D/E/F/G/H : 4850264

Update to V2.04

GP-320B

GH-8299

No Remedy Available

GP-330B

*Serial Numbers Before : 4457-7001

GH-8299

No Remedy Available

WS-200

GH-8299

No Remedy Available

FA-50

GN8093D/E/F/G/H : 4850264

Update to V2.02

FA-150

GN8093D/E/F/G/H : 4850264

Update to V4.07

SC-30

GN8094C/D/E/F/G : 4850263

Update to V3.03

SC-50/110

GN8094C/D/E/F/G : 4850263

Update to V2.02

**FELCOM-15/16

GN8097B/C/D : 4850296

Update to V3.13 / V5.07

**FELCOM-18

*Serial Numbers Before : 4507-4045

GN8097B/C/D : 4850296

Update to V1.20

**FELCOM-19

*Serial Numbers Before : 3599-2507

GN8097B/C/D : 4850296

Update to V1.20



** FELCOM-15 / FELCOM-16 / FELCOM-18 / FELCOM-19 – These units will only be affected by the GPS Rollover event if they are using the built in GPS receiver. If these units are connected to external GPS data, no action required. 

Future Rollover dates :

  • September 9th 2028

  • January 28th 2029



COLD START / MEMORY CLEAR PROCEDURE

 

MODEL


PROCEDURE


GP-70MK2

Menu > 0 > NEXT > NEXT > Down Arrow > Reverse Mark > ENT

GP-188

Menu > 9 > 9 > 0 > 9 > 1 > 8 > 8 > ENT

GP-80

Menu > 9 > 9 > Clear GPS > Yes > ENT

GP-90

Menu > 9 > 9 > Clear GPS > Yes > ENT

GP-150

Menu > 9 > 9 > Clear GPS > Yes > ENT

GP-1640

Menu > Configuration > System Menu > Memory/Trip Clear > Clear GPS Memory

GP-1650 / GP1850

Menu > Configuration > System Menu > Memory/Trip Clear > Clear GPS Memory

GP-280 / GP-380 / GP-680

Menu > 9 > 2 > Cold Start > Yes

GP-1800

Menu > 9 > Clear Memory > GPS > ENT

*Then turn power off / on

GP-500 Mk2

Menu > 9 > 6 > CLR > 1 > ENT

FRS-1000

PLTR MENU/ESC > 0 > 7 > Page 4 “Back to Defaults” > GPS RCVR > ENT > ENT

PS-8000 Mk2

PLTR MENU/ESC > 0 > 7 > Clear Memory > GPS > ENT > ENT

GP-7000

Menu > Advanced > Input/Output > Internal GPS setup > Restart GPS

GP-8000

Menu > 8 > Down Arrow > Clear Memory > All

GP-3100 / GP-3300

Menu > 8 > GPS Initial Settings > Cold Start > Yes

GP-3500

Menu 0 > 6 > 5 > GPS Cold Start

GP32 / GP-37

Menu > Erase > ENT > GPS Data > ENT > Erase GPS Data > Yes > ENT

GP-33

Menu > System > ENT > Reset > ENT > GPS > ENT > On > ENT > Yes > ENT

GP-320B

When NAV1 is connected it is available from “GPS Sensor Settings”

GP-330B

Unit activates a Cold Start at every start up

WS-200

Unit activates a Cold Start at every start up

FA-50

Cold Start from Menu is not available

FA-150

Menu > Diagnostics > Memory Clear > GPS Cold Start

SC-30

Unit activates a Cold Start at every start up

SC-50 / SC-110

Menu > Erase > GPS Data > Yes > ENT

FELCOM-15/16

Cold Start from Menu is not available

FELCOM-18/19

Cold Start from Menu is not available







rollover gps

Was this article helpful?

Yes
No
Give feedback about this article

Related Articles

  • Magnetron Lead Wire Change
  • Furuno Transducer Compatibility Guide
Portsmouth
West Building
Penner Road
Havant, Hampshire
PO9 1QY

Tel: 02392 441000
Email: sales@furuno.co.uk
Fraserburgh
South Breakwater
Fraserburgh
Aberdeenshire
AB43 9TD

Tel: 01346 518300
Email: sales@furuno.co.uk
> Furuno International
> Navnet Brochure
> General Brochure


> Privacy Policy
FacebookInstagramLinkedinYoutube
© 2021 Copyright © FURUNO (UK) LTD. All Rights Reserved.

Knowledge Base Software powered by Helpjuice

Definition by Author

0
0
Expand